M400手持压力和毫安校准仪/数据记录仪
M400手持压力和毫安校准仪/数据记录仪简单介绍
Meriam’s NEW M4 Series Handheld Precision Calibrator / Data Logger boasts an impressive array of features, functions and a terrific accuracy specification! The M400 includes one pressure sensor and one mA/V instrument. Chose from differential, gauge, compound or absolute pressure types and ranges from 10" H2O to 3000 PSIG full scale. Need two ranges for wider utility? No problem! The M402 can be configured with any two compound or absolute type sensors. See the table below for all the possibilities. Accuracy is ±0.025% of Reading from 10 to 100% of range and ±0.002% of Full Scale below 10% of range. Accuracy is maintained over operating temperatures from -20º to +50º C (-4º to +122º F). Data Logging is standard on all models. All M4 Series handhelds provide convenient electrical signal measurement and sourcing. Measure ±50V or ±100mA, source 24VDC and measure mA, sink V or mA, or source precise VDC or mA DC values using the supplied test leads. Accuracy is ±(0.015% of Reading + 0.002 units) over the entire operating temperature range. Source or sink values are easily entered using the Adaptive Interface Wheel.
M400 手持压力和毫安校准仪/数据记录仪的详细介绍
M400 Single Pressure Sensor, CE Mark
M400M400 Single Pressure Sensor, CE Mark
Handheld Pressure and mA Calibrator / Data Logger
Meriam’s NEW M4 Series Handheld Precision Calibrator / Data Logger boasts an impressive array of features, functions and a terrific accuracy specification! The M400 includes one pressure sensor and one mA/V instrument. Chose from differential, gauge, compound or absolute pressure types and ranges from 10" H2O to 3000 PSIG full scale. Need two ranges for wider utility? No problem!
The M402 can be configured with any two compound or absolute type sensors. See the table below for all the possibilities. Accuracy is ±0.025% of Reading from 10 to 100% of range and ±0.002% of Full Scale below 10% of range. Accuracy is maintained over operating temperatures from -20º to +50º C (-4º to +122º F). Data Logging is standard on all models.
All M4 Series handhelds provide convenient electrical signal measurement and sourcing. Measure ±50V or ±100mA, source 24VDC and measure mA, sink V or mA, or source precise VDC or mA DC values using the supplied test leads. Accuracy is ±(0.015% of Reading + 0.002 units) over the entire operating temperature range. Source or sink values are easily entered using the Adaptive Interface Wheel.
M4 Series Data Sheet
M4 Series Manual
Temperature:
Operating: -4 to 122°F (-20 to 50°C)
Storage: -40 to 140°F (-40 to 60°C)
Connections:
Pressure: 1∕8" NPT (female)
Electrical: Standard banana jacks on ¾" centers Firmware updates, data retrieval: USB mini-B (female)
Power:
Portable service: Four (4) AA alkaline batteries provides 30+ hours of continuous measurement service
Operation with PC: Power over USB using USB type A to mini-B cable (requires high power 500 mA port)