        X76LVC检漏系统The Series X76LVC is designed to monitor liquid level, vapor density, pressure and hydrostatic pressure. The system generates an alarm and may shut down specific facilities if preset parameters are exceeded. The microprocessor based system provides visual and audible alarms, self-diagnostics and sensor failure indication, fail-safe shutdown and auxiliary switch outputs for communications to a facility抯 remote displays.
    X76LVC检漏系统的详细介绍
    X76LVC检漏系统
    Leak Detection System [X76LVC]
        monitor liquid level, vapor density, pressure and hydrostatic pressure. The system generates an alarm and may shut down specific facilities if preset parameters are exceeded. The microprocessor based system provides visual and audible alarms, self-diagnostics and sensor failure indication, fail-safe shutdown and auxiliary switch outputs for communications to a facility抯 remote displays.
        The liquid level sensors will indicate presence of liquids in the annular space of double-wall tanks, secondary containment pipes, manhole or caisson compartments and in-tank high level to prevent overfill. The vapor density, measured by the product抯 unique vapor transducer, is indicated on the appropriate plug-in module in parts per million (ppm) by means of a 4?digit LED display. The display not only indicates the initial background vapor density in a vadose well or the annulus of any secondarily contained vessel, but also monitors an increasing trend of vapor density. The self-contained display also provides the ability to set the alarm and shutdown setpoints without additional calibration equipment.
        The pressure measurement utilized to monitor pressurized supply piping reads the pressure decay caused by a leak rate greater than 0.1 gph occurring between automatic test cycles.
        A hydrostatic measurement is applied to the annulus of a double-wall tank by detecting a loss of pressure in the pressurized cavity or the loss of liquid level in a reservoir or the annulus of the tank. The X76LVC System, housed in an attractive wall mounted NEMA Type 1 Enclosure, contains the intrinsically safe barrier interface to the transducers, a number of three channel alarm modules, vapor modules, and/or dispenser modules. The front door mounted audible alarm and the flashing alarm lights are acknowledged by the ACK button and functionally tested by means of the TEST push button.

     
    X76LVC检漏系统Leak Detection Measurement
    CSLD & Inventory Management 
    Leak Detection & Inventory Management.
    Environmental Management Software 
    Single or Double-wall Line Monitors
    Hydrocarbon Vapor Monitors 
    Above Ground Tank Monitors
     
     
  • 留言

    *详细需求:
    *手  机:
    联 系 人:
    电    话:
    E-mail:
    公  司:
    谷瀑服务条款》《隐私政策
珠海康宝莱仪表有限公司 电话:0756-3895880 手机:13928079019 地址: 珠海市香州区华达工业区8栋
内容声明:谷瀑为第三方平台及互联网信息服务提供者,谷瀑(含网站、客户端等)所展示的商品/服务的标题、价格、详情等信息内容系由店铺经营者发布,其真实性、准确性和合法性均由店铺经营者负责。谷瀑提醒您购买商品/服务前注意谨慎核实,如您对商品/服务的标题、价格、详情等任何信息有任何疑问的,请在购买前通过谷瀑与店铺经营者沟通确认;谷瀑上存在海量店铺,如您发现店铺内有任何违法/侵权信息,请在谷瀑首页底栏投诉通道进行投诉。